ASTM G85 A5 Test
Dilute Electrolyte Cyclic Fog/Dry Test
In this test cycles of 1hr dry-off and 1hr fog are utilized. The electrolyte is a solution of sodium chloride and ammonium sulfate and is more dilute than the traditional salt spray fog test. The fog portion of this test is conducted at room temperature, the dry-off portion, however, is performed at an elevated temperature. Also the spray atomizing air is not saturated with water for this test.
The electrolyte solution consists of 0.05% sodium chloride and 0.35% ammonium sulfate by mass. The sodium chloride and water are subject to the same purity requirements as for the other test in this specification. The ammonium sulfate shall not contain more than 0.3% total impurities. To obtain complete specifications go to ASTM International.
The temperature throughout the exposure zone during the dry-off phase shall reach and remain constant at 35°C plus or minus 6 1.5°C (95°F plus or minus 3°F) within 3/4-h of switching from the fog period to the dry period.
For further information on ASTM standards visit; https://www.astm.org/
The information may be slightly different from the official version, and all information is based on official website information.